Editing of Input / Output Size
You can change the input/output size of the CC-Link slave module. Change the input/output size as necessary.
Select [Setup] - [System Configuration] and display the [System Configuration] dialog box.
Select [Controller] - [Inputs / Outputs] - [Fieldbus Slave] - [General].
Change the settings of [Version] of CC-Link.
In this example, Version is changed to "2.00".Change the settings of [Extended Cyclic Setting].
In this example, Extended Cyclic Setting is changed to "2".Change the settings of [Input Byte] and [Output Byte].
In this example, both of them are changed to "92" Bytes. In this example, both of them are changed to "92" Bytes.Click [Apply].
Click [Close].
The following dialog box appears and the Controller automatically starts rebooting.Select [Setup] - [System Configuration] and display the [System Configuration] dialog box.
Select [Controller] - [Inputs / Outputs].
Confirm that the following items are displayed in "Fieldbus slave".
Inputs: 512 - 1247
Outputs: 512 - 1247In this example, Input byte is 92 bytes (736 bits) and 512-1247 is displayed in Inputs.
Also, Output byte is 92 bytes (736 bits) and 512-1247 is displayed in Outputs.
Click [Close].