Epson RC+ 8.0 Configuration
To use the Fieldbus master board, the Robot system option setting and fieldbus master setting should be enabled in Epson RC+ 8.0.
Select [Setup] - [License Configuration] and open [License Configuration] dialog.
Enable the Fieldbus Master option.
Refer to the following section for details.
"Epson RC+ 8.0 User's Guide - Installing Controller License"
Select [Setup] - [System Configuration] and display the [System Configuration] dialog box.
Select [Controller] - [Inputs/Outputs] - [Fieldbus Master] - [General].
Set the following items:
Fieldbus Type: PROFINET
Board Type: Hilscher
Update Interval: Update cycle for the PROFINET master I/OClick [Import Configuration].
Select the configuration file (.csv) for RC+.
Click [Open].Confirm that the configuration file (.csv) for RC+ is imported and click [OK].
Click [Apply]. Confirm that following items are displayed.
Total Input Bytes: Number of inputs the master controls (Bytes)
Total Output Bytes: Number of outputs the master controls (Bytes)Click [Close].
The following dialog box appears and the Controller automatically starts rebooting.