Epson RC+ 8.0 Configuration

To use the Fieldbus master board, the Robot system option setting and fieldbus master setting should be enabled in Epson RC+ 8.0.

  1. Select [Setup] - [License Configuration] and open [License Configuration] dialog.

  2. Enable the Fieldbus Master option.

    Refer to the following section for details.

    "Epson RC+ 8.0 User's Guide - Installing Controller License"

  3. Select [Setup] - [System Configuration] and display the [System Configuration] dialog box.

  4. Select [Controller] - [Inputs/Outputs] - [Fieldbus Master] - [General].

  5. Set the following items:
    Fieldbus Type: PROFINET
    Board Type: Hilscher
    Update Interval: Update cycle for the PROFINET master I/O

    Click [Import Configuration].

  6. Select the configuration file (.csv) for RC+.
    Click [Open].

  7. Confirm that the configuration file (.csv) for RC+ is imported and click [OK].

  8. Click [Apply]. Confirm that following items are displayed.

    Total Input Bytes: Number of inputs the master controls (Bytes)
    Total Output Bytes: Number of outputs the master controls (Bytes)

  9. Click [Close].
    The following dialog box appears and the Controller automatically starts rebooting.