Referencing points by point label
You can assign names to point numbers so you can refer to points by name in a program.
Assign names on [Robot Manager]-[Point Data] tab on the toolbar or from the editor of the point data in the Epson RC+ 8.0 menu-[File]-[Open File]. Names must be unique for each point number when used in the same point file.
Point labels can include up to 32 bytes of alphanumeric, Japanese, Chinese, and underscore characters. However, the first character must be an English, Japanese, or Chinese character. Only alphabets and Japanese can be used for the first letter.
For i = 0 To 10
Go pick
Jump place