Command 950: Sets the condition for using Sense with command 2002 and 2003
Sets the Sense condition.
Command Syntax
| bit | Name | Description | |
|---|---|---|---|
| Parameter 1 | 15 | I/O number (bit) | Specifies the bit I/O number to be used to the input condition. |
| 14 | |||
| | | |||
| 1 | |||
| 0 |
| bit | Name | Description | |
|---|---|---|---|
| Parameter 2 | 15 | reserved | Specify “0”. |
| | | |||
| 2 | |||
| 1 | I/O type | 0 = I/O 1 = memory I/O | |
| 0 | logic | Specifies the logic to satisfy the condition 0 or 1 |
Response Syntax
Refer to the following.
Description
Specifies the bit I/O number to be used for the input condition and the logic to meet the condition.
Example
When setting the condition under the timing when port number 100 turns ON.
| Command | Response |
| 03B6H 0064H 0001H | 03B6H 0000H 0000H |