Cnv_Downstream Statement

Sets the downstream limit of the specified conveyor.

Syntax
Cnv_Downstream (conveyorNumber) , lowerLimit

Parameters

conveyorNumber
Specify the conveyor number as an expression or a number (1-16).
lowerLimit
A border on the downstream side of the tracking area

Description
By using Cnv_Downstream, you can change the downstream limit which was set in the calibration wizard. However, if skewed downstream limit is used, you cannot change the value by Cnv_Downstream.

Note


This command will only work if the Conveyor Tracking option is active.


See Also
Cnv_Upstream

Cnv_Downstream Statement Example

Cnv_Downstream 1,500