Cnv_Upstream Statement

Sets the upperstream limit of the specified conveyor.

Syntax
Cnv_Upstream (conveyorNumber), upperLimit

Parameters

conveyorNumber
Specify the conveyor number as an expression or a number (1-16).
upperLimit
Set a border on the upstream side of the tracking area.

Description
By using Cnv_Upstream, you can change the upperstream limit which was set in the calibration wizard. However, if skewed upperstream limit is used, you cannot change the value by Cnv_Upstream.

Note


This command will only work if the Conveyor Tracking option is active.


See Also
Cnv_Downstream

Cnv_Upstream Statement Example

Cnv_Upstream 1,200