Command 801: Sets the lower limit pulse value

Defines the lower limit for the permissible working range of the specified joint in pulses.

Command Syntax

bit Name Description
Parameter 1 15 jointNumber Specifies the joint number by an integer from 1 to 6.
14
1
0
bit Name Description
Parameter 2 15

lowerLmit

High-order side

Integer in complement form representing the lower limit pulse of the motion range for the specified joint.

High-order side 16 bit.

14
1
0
bit Name Description
Parameter 3 15

lowerLmit

Low-order side

Integer in complement form representing the lower limit pulse of the motion range for the specified joint.

Low-order side 16 bit.

14
1
0

Response Syntax

Refer to the following.

Response Codes

Description

This command specifies the lower limit pulse when setting the pulses separately.

This command functions in combination with Command 801.

To set pulses, execute Command 801 and Command 802, in that order. The settings will be effective after issuing Command 802.

If commands other than Command 802 are issued after this command, setting will be canceled.

Example

When setting – 6000 for the lower limit pulse of the Joint #1 and 7000 for the upper limit pulse.

Command Response

0321H 0001H FFFFH E890H

0322H 0001H 0000H 1B58H

0321H 0000H 0000H