Command 804: Acquires the allowable motion area pulse setting value by specifying the lower limit pulse

Acquires the upper limit of the motion range area setting in pulses.

Command Syntax

bit Name Description
Parameter 1 15 jointNumber Specifies the joint number by an integer from 1 to 6.
14
1
0

Response Syntax

bit Name Description
Response 1 15 jointNumber Specifies the joint number by an integer from 1 to 6.
14
1
0
bit Name Description
Response 2 15

upperLmit

High-order side

Integer in complement form representing the upper limit pulse of the motion range for the specified joint.

High-order side 16 bit.

14
1
0
bit Name Description
Response 3 15

upperLmit

Low-order side

Integer in complement form representing the upper limit pulse of the motion range for the specified joint.

Low-order side 16 bit.

14
1
0

Description

Acquires the current upper limit pulse of the permissible motion range of the specified joint.

The pulse value is returned in 32-bit two’s complement format.

Example

When setting – 6000 for the lower limit pulse of the Joint #1 and 7000 for the upper limit pulse.

Command Response
0325H 0001H 0325H 0001H 0000H 1B58H