ArmCalibSet Statement
Configures and displays arm length and joint offset settings.
Syntax
(1) ArmCalibSet setValue1, setValue2, setValue3
(2) ArmCalibSet
Parameters
setValue | SCARA robots |
---|---|
1 | Horizontal distance from joint #1 to joint #2 (mm) |
2 | Horizontal distance from Joint #2 to orientation center (mm) |
3 | Joint #2 angle offset (°) |
Return Values
When the ArmCalibSet instruction is executed without all parameters, the system displays arm length calibration parameters.
Description
ArmCalibSet sets parameters related to the arm length and joint offsets. Distance accuracy can be increased by using the length and joint offset of each arm that were precisely calculated at the factory and configuring settings using this command.
Note
Do not use ArmCalibSet unless absolutely necessary.
ArmCalibSet contains factory settings that have been precisely set. (When purchasing the Arm Length Calibration Option) Accidentally changing these settings adversely affects distance accuracy and trajectory accuracy. Do not change ArmCalibSet unless absolutely necessary.
See Also
ArmCalib, ArmCalibClr, ArmCalibDef
ArmCalibSet Statement Example
The following example is executed from the Command window.
> ArmCalibSet 299.989, 250.001, 0.012