Command 402: Sets the approach distance of the arch parameter

Sets Arch approach distance.

Command Syntax

bit Name Description
Parameter 1 15 archNumber Specifies the arch number by an integer from 0 to 6. Valid values are integers from 0 to 6.
14
1
0
bit Name Description
Parameter 2 15

approachDistance

High-order word

Specifies the approach distance after the completion of horizontal movement as the value (Unit: mm) × 1000 converted to a 32-bit integer.

High-order side 16 bit.

14
1
0
bit Name Description
Parameter 3 15

approachDistance

Low-order word

Specifies the approach distance after the completion of horizontal movement as the value (Unit: mm) × 1000 converted to a 32-bit integer.

Low-order side 16 bit.

14
1
0

Response Syntax

Refer to the following.

Response Codes

Description

This command is used to set the approach distance when setting Arch parameters separately.

This command must be used in combination with Command 402.

To set the parameters, execute Command 401 and 402, in that order. The settings will be effective after issuing Command 402.

If the last command is not the command No. 401, an error response will be returned.

Example

When setting 10.123 mm for the depart distance and 20.123 mm for the approach distance in the Arch number 3.

Command Response