Command 2105: Turns ON the output of the specified bit port

Turns ON the specified output bit.

Command Syntax

bit Name Description
Parameter 1 15 bitNumber Specifies the bit number to be turned ON.
14
1
0

Response Syntax

Refer to the following.

Response Codes

Description

The command turns ON (sets to 1) the specified output.

CAUTION


  • Output bits configured as remote
    If an output bit which was set up as remote is specified, an error will occur. Remote output bits are turned ON or OFF automatically according to system status.
  • When an emergency stop occurs
    The Controller has a feature which causes all outputs to go off when an E-Stop occurs. To keep the setting in emergency, follow the procedure described in the following.
    “Epson RC+ User’s Guide” - [Setup]-[System Configuration]-[Controller]-[Preferences]-Output port OFF with emergency stop”

Example

When turning ON the output bit number 15.

Command Response
0839H 000FH 0839H 0000H 0000H