Command 2106: Turns OFF the output of the specified bit port
Turns OFF the specified output bit.
Command Syntax
| bit | Name | Description | |
|---|---|---|---|
| Parameter 1 | 15 | bitNumber | Specifies the bit number to be turned OFF. |
| 14 | |||
| | | |||
| 1 | |||
| 0 |
Response Syntax
Refer to the following.
Description
The command turns OFF (sets to 0) the specified output.
CAUTION
- Output bits configured as remote
If an output bit which was set up as remote is specified, an error will occur. Remote output bits are turned ON or OFF automatically according to system status. - When an emergency stop occurs
The Controller has a feature which causes all outputs to go off when an E-Stop occurs. To keep the setting in emergency, follow the procedure described in the following.
“Epson RC+ User’s Guide"
Example
When turning OFF the output bit number 15.
| Command | Response |
| 083AH 000FH | 083AH 0000H 0000H |