Command 2106: Turns OFF the output of the specified bit port

Turns OFF the specified output bit.

Command Syntax

bit Name Description
Parameter 1 15 bitNumber Specifies the bit number to be turned OFF.
14
1
0

Response Syntax

Refer to the following.

Response Codes

Description

The command turns OFF (sets to 0) the specified output.

CAUTION


  • Output bits configured as remote
    If an output bit which was set up as remote is specified, an error will occur. Remote output bits are turned ON or OFF automatically according to system status.
  • When an emergency stop occurs
    The Controller has a feature which causes all outputs to go off when an E-Stop occurs. To keep the setting in emergency, follow the procedure described in the following.
    “Epson RC+ User’s Guide"

Example

When turning OFF the output bit number 15.

Command Response
083AH 000FH 083AH 0000H 0000H