Command 1200: Sets the current manipulator position to the specified point
Sets the current manipulator position to the point.
Command Syntax
| bit | Name | Description | |
|---|---|---|---|
| Parameter 1 | 15 | pointNumber | Specifies the point number. |
| 14 | |||
| | | |||
| 1 | |||
| 0 |
Response Syntax
Refer to the following.
Description
Sets the current manipulator position to the specified point.
Example
When setting the current position to P1.
| Command | Response |
| 04B0H 0001H | 04B0H 0000H 0000H |