[Synchronize Project] Command (Project Menu)

If following conditions are fulfilled when PC and Controller are connected, [Synchronize Project] can be selected.

  • When the project name on the PC and on the Controller was the same.
  • When the file in the Controller has been changed after the last project build on the PC.

How to set the synchronization

  1. Select Epson RC+ 8.0 Menu-[Project]-[Synchronize Project]. The message shown below will appear.

  2. Click the [OK] button.

  3. The dialog shown below appears. Select the method of synchronization and click the [Start] button.

  4. The project on the PC and on the Controller synchronized.

Item Description
Synchronization Method Select the method of synchronization.
  • When the "Send files only from PC to Controller" is selected, the file on the PC is copied to the Controller.
  • When the "Send files only from Controller to PC" is selected, the file on the Controller is copied to the PC.
Function Displays the file type.
File Name List of files in the project.
PC Files The update timestamps for PC files.
Direction Indicates the direction of file transfer.
  • -->: PC to Controller.
  • <---: Controller to PC.
  • None: It cannot be synchronized because the files are the same.
  • Select: It is indicated in pink. The direction of file transfer needs to be selected by user because the file was changed after the last project build on PC.
Controller Files The update timestamps for Controller files.
Sending Status Indicates the status of the file.
  • Waiting to send: Waits for synchronization method to be selected.
  • Synchronized: The files are the same.
Start Starts the synchronization.
Close Closes [Synchronize Project] dialog. When [Close] button clicked without project synchronization, error 10015 "Project could not be synchronized." is displayed. The synchronization will not be done and connection to the Controller will disconnected.

When "Send files only from PC to Controller" is selected for Synchronization Method:

When "Send files only from Controller to PC" is selected for Synchronization Method: