Signal Connections
Signal connections of Controller PULSE IN connector
The signal connections of the PULSE IN connector, which is the Controller's conveyor tracking I/F port, are shown in the table below.
Pin | Dir | Signal | Description |
---|---|---|---|
1 | In | +A2 | Phase +A signal for Counter 2 for CH2 |
2 | In | +B2 | Phase +B signal for Counter 2 for CH2 |
3 | In | +A1 | Phase +A signal for Counter 1 for CH1 |
4 | In | +B1 | Phase +B signal for Counter 1 for CH1 |
5 | In | TRG1_IN | Trigger input for Counter 1 |
6 | In | -A2 | Phase -A signal for Counter 2 for CH2 |
7 | In | -B2 | Phase -B signal for Counter 2 for CH2 |
8 | In | -A1 | Phase -A signal for Counter 1 for CH1 |
9 | In | -B1 | Phase -B signal for Counter 1 for CH1 |
10 | - | GND | Power supply ground |
11 | In | TRG2_IN | Trigger input for Counter 2 |
12 | Com | TRG2_COMMON | Trigger common for Counter 2 for CH2 |
13 | Com | TRG1_COMMON | Trigger common for Counter 1 for CH1 |
14 | - | GND | Power supply ground |
15 | Out | +24V | 24V power supply for encoder power generation |
Carefully note the following when creating a cable for conveyor tracking applications.
CAUTION
24 VDC for operation of conveyor tracking option kit B is supplied through the PULSE IN connector. Use carefully as explained below.
- Do not connect anything other than a conveyor tracking cable to the PULSE IN connector. Otherwise, connected equipment and Controllers may get damaged.
- Do not use 24 VDC even if the customer prepares conveyor tracking cable. Our guarantee does not cover damage to connected equipment or Controllers used in this way.
- Commercially available D-SUB 15-pin cables cannot be used due to different pin assignments and wiring. When preparing cables yourself, follow the table, ensuring that the pin assignments and wiring are correct.
Signal connections of PULSE OUT connector with conveyor tracking option kit B
The signal connections of PULSE OUT connectors with conveyor tracking option kit B is shown in the table below.
Pin | Dir | Signal | Description |
---|---|---|---|
1 | Out | +A2 | Phase +A signal for Counter 2 for CH2 |
2 | Out | +B2 | Phase +B signal for Counter 2 for CH2 |
3 | Out | +A1 | Phase +A signal for Counter 1 for CH1 |
4 | Out | +B1 | Phase +B signal for Counter 1 for CH1 |
5 | Out | TRG1_IN | Trigger input for Counter 1 |
6 | Out | -A2 | Phase -A signal for Counter 2 for CH2 |
7 | Out | -B2 | Phase -B signal for Counter 2 for CH2 |
8 | Out | -A1 | Phase -A signal for Counter 1 for CH1 |
9 | Out | -B1 | Phase -B signal for Counter 1 for CH1 |
10 | - | GND | Power supply ground |
11 | Out | TRG2_IN | Trigger input for Counter 2 |
12 | Com | TRG2_COMMON | Trigger common for Counter 2 for CH2 |
13 | Com | TRG1_COMMON | Trigger common for Counter 1 for CH1 |
14 | - | GND | Power supply ground |
15 | In | +24V | 24V power supply for encoder power generation |
CAUTION
Do not connect cables other than those supplied with conveyor tracking option kit B. Such cables may damage connected equipment and conveyor tracking pulse boxes.
Signal wiring for encoder connectors (CH1, CH2) with conveyor tracking option kit B
The signal connections of CH1 and CH2, the encoder connection terminals (a) for users, are shown in the table below. The pins are arranged in the order of 1→8 as printed on the main unit, and CH1 and CH2 have the same signal connections.
CH1
Pin | Dir | Signal | Description |
---|---|---|---|
1 | In | +B1 | Phase +B signal for Counter 1 |
2 | In | -B1 | Phase -B signal for Counter 1 |
3 | In | +A1 | Phase+ A signal for Counter 1 |
4 | In | -A1 | Phase -A signal for Counter 1 |
5 | In | TRG1_IN | Trigger input for Counter 1 |
6 | Com | TRG1_COMMON | Trigger common for Counter 1 |
7 | GND | GND | Power supply ground for +5 V power supply for encoder |
8 | Out | +5V | +5 V power supply for encoder |
CH2
Pin | Dir | Signal | Description |
---|---|---|---|
1 | In | +B2 | Phase+ B signal for Counter 2 |
2 | In | -B2 | Phase- B signal for Counter 2 |
3 | In | +A2 | Phase+ A signal for Counter 2 |
4 | In | -A2 | Phase- A signal for Counter 2 |
5 | In | TRG2_IN | Trigger input for Counter 2 |
6 | Com | TRG1_COMMON | Trigger common for Counter 2 |
7 | GND | GND | Power supply ground for +5 V power supply for encoder |
8 | Out | +5V | +5 V power supply for encoder |
- Our conveyor system does not require Z-phase wiring. Insulate to prevent contact with panel, etc.
- Pins 1 to 4: Connect to encoder output +A, -A, +B, and -B.
- Pins 5 to 6: When latching conveyor pulse by external signal, connect to latch signal. Exactly when the signal is turned OFF to ON, the encoder pulse is latched.
- Pins 7 to 8: 5 V power supply and GND for encoders. Connect GND to 7 and power supply terminal to 8.
- Wiring shield screw: Secure the wiring shield with the shield fastening screw (b) on top of the connector.