Flip & Separate Test & Adjust
Test and adjust the flip and separate parameters. This item is displayed as "Separate" when Flip is disabled. (Refer General )
[Test & Adjust] tab on the screen below.
Description of display items
Items | Description |
---|---|
Perform centering before separation | If checked, perform the centering operation before the separation operation during the test operation. This applies only to test operation. |
Amplitude | Set the strength of the amplitude of the vibration. Unit: % |
Duration | Set the duration of the vibration. Unit: ms |
Frequency | Set the frequency of the vibration. Unit: Hz |
Guidelines for adjustment
The objective is to have the parts evenly distributed across the platform. Adjust the amplitude and frequency so that the part can disperse or reorient itself as quickly as possible and do not fly off the platform.
Set the vibration time to the shortest time that the part can be fully dispersed or reoriented.
Test
- Put in an appropriate number of parts (e.g., optimal number of parts).
- Click the [Run] button.
- Check the operation.
Adjust the parameters as needed and click the [Run] button again.
Refer to the following for further details.
How To Adjust Feeder Parameters