Purge Test & Adjust

Test and adjust the purge parameters. This item is displayed when Purge enabled.
Refer to the following section for further details.
Prevent Interference with Hand

Description of display items

Items Description
Amplitude

Set the strength of the amplitude of the vibration.

Unit: %

Duration

Set the duration of the vibration.

Unit: ms

Frequency

Set the frequency of the vibration.

Unit: Hz

Purge Gate Operate the Purge Gate.
Purge Gate Closed

Status indicator for the Purge Gate sensor

Closed : Green, Not closed : Gray

Open / Close Allows opening and closing of the Purge Gate

KEY POINTS


Even if the vibration amplitude is set to 0%, the feeder will still vibrate slightly.

This is a specification.

KEY POINTS


Purge Gate Closed will only be accessible if the "Purge Gate Installed" check box was checked in the Epson RC+ 8.0 Menu - [Setup] - [System Configuration] - [Controller] - [Part Feeders].

KEY POINTS


If you try to move to another tab when the Purge Gate is not closed, the dialog "Purge gate will now be closed. Continue?" is displayed. Press OK to close the Purge Gate.

Guidelines for adjustment; Adjust the amplitude and frequency so that the part is ejected from the feeder as quickly as possible.
Set the vibration time to the time it takes for the parts to be completely ejected.

Test

  1. Put in an appropriate number of parts (e.g., optimal number of input parts).
  2. Open the purge gate (provided by the customer).
    In the case of the IF-80, empty the purge box (optional).
  3. Click the [Run] button.
  4. Check the operation.
    Adjust the parameters as needed and click the [Run] button again.
    Refer to the following for further details.
    How To Adjust Feeder Parameters